PET

CASToR - XEMIS2

Extension of the CASToR framework dedicated to multi-class reconstruction of medical images and Fisher information matrix estimation for $3\gamma$ PET/Compton imaging from continuous photon detections.

ORION

A Monte Carlo simulator for multi-class sensitivity maps estimations, compatible with CASTOR, designed for XEMIS2.

INPACT 2024 - Art et Sciences

Presentation of research thesis works on $3\gamma$ imaging within the [INPACT](https://www.ec-nantes.fr/engineering-programme-diplome-dingenieur/course-specialisations-yrs-23/engineering-and-digital-sciences-for-art-culture-and-heritage?l=1) professional option "Engineering for art, culture and heritage" at the Ecole Centrale de Nantes.

Reconstruction multiclasse pour l'imagerie TEP 3-photons

This contribution addresses the problem of image reconstruction of radioactivity distribution for which the available information arises from several classes of data, each associated with a specific combination of detections

Multi-class maximum likelihood expectation-maximization list-mode image reconstruction, an application to three-gamma imaging

Our contribution focuses at improving the image reconstruction process for specific Compton imaging systems able to detect multiple classes of events, in the field of nuclear imaging.

Challenges and opportunities of $3\gamma$ tomographic reconstruction for the XEMIS camera

Workshop [Emily](https://emilyworkshop.github.io/) November 2022 – Conference in Lyon dedicated to Emission Imaging.

Challenges and opportunities of $3\gamma$ tomographic reconstruction for the XEMIS camera

LS2N PhD Student’s Seminar – October 2022.

POLLUX

A Monte Carlo simulator for $3\gamma$ imaging using the XEMIS2 camera, designed to generate synthetic data for the development and evaluation of multi-class reconstruction algorithms developed in CASToR framework.

NIST PARSER

A Bash script for extracting and formatting the photon cross sections from the [NIST](https://physics.nist.gov/PhysRefData/Xcom/html/xcom1.html) database, which are used in Monte Carlo simulation softwares for $3\gamma$ PET imaging.

Reconstruction tomographique pour l’imagerie TEP à $3\gamma$

June 2022 – SiMS PhD student seminar (in French).